Configuration 1
A fluoroplastic sump pump for corrosive liquid transfer from tanks and pits. The supplied technical sheets are from the HYF manual. Confirm immersed length, liquid level, fluoroplastic grade and shaft-sealing arrangement.

Fluoroplastic Sump Pump
A fluoroplastic sump pump for corrosive liquid transfer from tanks and pits.
Related resources: Chemical and petrochemical pump selection
models
Check model references against the original performance table, speed, materials and operating conditions.
| Model reference | Catalogue scope | Specifications | Enquiry |
|---|---|---|---|
| 25HYF-41 | Original catalogue reference | Source PDF ↗ | |
| 25HYF-25 | Original catalogue reference | Source PDF ↗ | |
| 25HYF-16 | Original catalogue reference | Source PDF ↗ | |
| 40HYF-40 | Original catalogue reference | Source PDF ↗ | |
| 40HYF-26 | Original catalogue reference | Source PDF ↗ | |
| 40HYF-16 | Original catalogue reference | Source PDF ↗ | |
| 50HYF-25 | Original catalogue reference | Source PDF ↗ | |
| 50HYF-16 | Original catalogue reference | Source PDF ↗ | |
| 65HYF-40 | Original catalogue reference | Source PDF ↗ | |
| 65HYF-25 | Original catalogue reference | Source PDF ↗ | |
| 65HYF-16 | Original catalogue reference | Source PDF ↗ | |
| 100HYF-57 | Original catalogue reference | Source PDF ↗ | |
| 100HYF-37 | Original catalogue reference | Source PDF ↗ | |
| 100HYF-23 | Original catalogue reference | Source PDF ↗ |
The supplied technical sheets are from the HYF manual. Confirm immersed length, liquid level, fluoroplastic grade and shaft-sealing arrangement.
configurations
A fluoroplastic sump pump for corrosive liquid transfer from tanks and pits. The supplied technical sheets are from the HYF manual. Confirm immersed length, liquid level, fluoroplastic grade and shaft-sealing arrangement.
A fluoroplastic sump-pump series for corrosive-liquid duties in chemical, pharmaceutical and environmental processes. The shared fact record identifies FYS, but the available parameter sheet is labelled HYF. It is not an FYS rating table. Request an FYS-specific curve and arrangement.
overview

The hydraulic end is immersed in the sump while the drive remains above the liquid. Tank depth, operating levels, mounting plate and column arrangement define the installation.
A fluoroplastic sump pump for corrosive liquid transfer from tanks and pits.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
construction

The hydraulic end operates below liquid level. Define the lowest and highest operating levels.

Confirm the actual FEP, PVDF or other specified grade against the complete liquid composition.

Immersion length and tank dimensions determine the shaft and support arrangement.

Match the installation plate, discharge connection and lifting clearance to the tank layout.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
duty requirements

Review medium name and composition, required flow, total head, operating temperature, suction conditions, installation arrangement, power supply and drive method, materials, standards and inspection requirements, required supply scope, full chemical composition and concentration, density and viscosity, flammability, toxicity, crystallisation and volatility, design pressure and temperature, seal and flushing requirements, applicable process standard together with the liquid composition, temperature and installation. The values on a catalogue page are not a substitute for checking the selected model curve and approved arrangement.
| Wetted components | Fluoroplastic; confirm exact grade |
|---|---|
| Sealing | Confirm immersed shaft and sealing design |
| Liquid / design limits | Confirm liquid composition, temperature, particles and operating conditions |
| medium name and composition | Include this information in the duty review and model selection |
| required flow | Include this information in the duty review and model selection |
| total head | Include this information in the duty review and model selection |
| operating temperature | Include this information in the duty review and model selection |
| suction conditions | Include this information in the duty review and model selection |
| installation arrangement | Include this information in the duty review and model selection |
| power supply and drive method | Include this information in the duty review and model selection |
| materials, standards and inspection requirements | Include this information in the duty review and model selection |
| required supply scope | Include this information in the duty review and model selection |
| full chemical composition and concentration | Include this information in the duty review and model selection |
| density and viscosity | Include this information in the duty review and model selection |
| flammability, toxicity, crystallisation and volatility | Include this information in the duty review and model selection |
| design pressure and temperature | Include this information in the duty review and model selection |
| seal and flushing requirements | Include this information in the duty review and model selection |
| applicable process standard | Include this information in the duty review and model selection |
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
installation

Provide tank dimensions, mounting-plate interfaces and operating liquid levels to determine immersion length.
Review column / shaft support, driver, discharge piping and maintenance clearance. Confirm bearing-flush requirements for the configuration.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
applications

For chemical processing, provide the complete composition, concentration, temperature and seal-utility requirements. Check the proposed arrangement against vertical tank / sump installation and fluoroplastic; confirm exact grade, then verify the operating point on the selected model curve.
For pharmaceutical processing, check the applicable product curve, liquid properties, required operating point and installation geometry. Check the proposed arrangement against vertical tank / sump installation and fluoroplastic; confirm exact grade, then verify the operating point on the selected model curve.
For metallurgy, check the applicable product curve, liquid properties, required operating point and installation geometry. Check the proposed arrangement against vertical tank / sump installation and fluoroplastic; confirm exact grade, then verify the operating point on the selected model curve.
For environmental services, check the applicable product curve, liquid properties, required operating point and installation geometry. Check the proposed arrangement against vertical tank / sump installation and fluoroplastic; confirm exact grade, then verify the operating point on the selected model curve.
supply scope
Define the pump configuration, installation interfaces, controls and documents in the quotation.

Hydraulic end, materials, sealing and interfaces for your driver or installation.

Pump and matched motor, coupling / transmission, base and guarding as applicable.

Agreed supports, controls, auxiliaries, spares and technical documents.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
manufacturing

Casting produces pump components to the construction and material requirements of the selected equipment. The applicable alloy, pattern and component geometry depend on the pump family and the agreed operating conditions.

Machining prepares mounting faces, bores, fits and connection interfaces for assembly. OEM parts should be reviewed against the approved drawing and revision, including the dimensions that determine interchange and installation.

Owner-supplied factory photograph showing pump castings staged in a work area. The exact parts and process route depend on the selected order.

Owner-supplied factory photograph showing test-control equipment. The inspection points and acceptance records must be agreed for the selected equipment.
documents
Original series manual and technical references. Review the applicable model, version and units.
Open original PDF View family brochure ↗Request the selected model curve, arrangement drawing, materials, installation instructions and agreed inspection records.
Request technical documentsquestions
medium name and composition; required flow; total head; operating temperature; suction conditions; installation arrangement; power supply and drive method; materials, standards and inspection requirements; required supply scope; full chemical composition and concentration; density and viscosity; flammability, toxicity, crystallisation and volatility; design pressure and temperature; seal and flushing requirements; applicable process standard. Review the complete duty on the applicable model curve.
Fluoroplastic; confirm exact grade. Confirm immersed shaft and sealing design. Confirm compatibility with the complete liquid composition and temperature.
Catalogue ranges summarize printed records and may combine different conditions. Check each model against its source curve and required speed.
Confirm pump, driver, controls, auxiliaries, spares, drawings, manuals and required test records in the agreed quotation.
enquiry
Describe the liquid, required output and site arrangement so BBP can review the model and equipment scope.