Pump hydraulic section
Use an ASJ-specific curve for the water demand and pumping water level.

Deep-Well Submersible Pump
A deep-well submersible pump for agricultural, municipal and industrial clear-water supply.
Related resources: Deep-well water supply requirements
models
Check model references against the original performance table, speed, materials and operating conditions.
Use the original model table with its stated speed, impeller and units. A catalogue range does not guarantee a combined operating point.
Request a curve & model scheduleoverview

The hydraulic end and motor operate below the liquid surface. Confirm the required flow and head together with submergence, cooling conditions, cable routing and lifting access.
A deep-well submersible pump for agricultural, municipal and industrial clear-water supply.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
construction

Use an ASJ-specific curve for the water demand and pumping water level.

The directly connected motor must operate fully immersed under the conditions in its manual.

Compare assembly diameter, well straightness and riser connections before installation.

Specify cable length and support. Lift by the intended lifting arrangement, never by the power cable.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
duty requirements

Review medium name and composition, required flow, total head, operating temperature, suction conditions, installation arrangement, power supply and drive method, materials, standards and inspection requirements, required supply scope, well diameter and depth, static and dynamic water levels, sand content and water-quality report, cable length and wellhead arrangement together with the liquid composition, temperature and installation. The values on a catalogue page are not a substitute for checking the selected model curve and approved arrangement.
| Wetted components | Wetted materials selected for the liquid and temperature |
|---|---|
| Sealing | Model-specific submerged arrangement |
| Liquid / design limits | Clear water; confirm sand and chemistry |
| medium name and composition | Include this information in the duty review and model selection |
| required flow | Include this information in the duty review and model selection |
| total head | Include this information in the duty review and model selection |
| operating temperature | Include this information in the duty review and model selection |
| suction conditions | Include this information in the duty review and model selection |
| installation arrangement | Include this information in the duty review and model selection |
| power supply and drive method | Include this information in the duty review and model selection |
| materials, standards and inspection requirements | Include this information in the duty review and model selection |
| required supply scope | Include this information in the duty review and model selection |
| well diameter and depth | Include this information in the duty review and model selection |
| static and dynamic water levels | Include this information in the duty review and model selection |
| sand content and water-quality report | Include this information in the duty review and model selection |
| cable length and wellhead arrangement | Include this information in the duty review and model selection |
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
installation

Compare well diameter, straightness and pumping water level with the assembly drawing. Define riser length and discharge connection.
Specify cable sizing, support, motor protection and lifting access. Follow the model-specific installation instructions.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
applications

For agricultural water supply, state demand, pumping water level, source quality and seasonal operating range. Check the proposed arrangement against submerged in a suitable well and wetted materials selected for the liquid and temperature, then verify the operating point on the selected model curve.
For municipal water supply, state demand, pumping water level, source quality and seasonal operating range. Check the proposed arrangement against submerged in a suitable well and wetted materials selected for the liquid and temperature, then verify the operating point on the selected model curve.
For industrial water supply, state demand, pumping water level, source quality and seasonal operating range. Check the proposed arrangement against submerged in a suitable well and wetted materials selected for the liquid and temperature, then verify the operating point on the selected model curve.
supply scope
Define the pump configuration, installation interfaces, controls and documents in the quotation.

Model-specific submerged pump, motor, materials and sealing.

Discharge connections, support, cable, lifting and applicable installation accessories.

Agreed starting, protection, process inputs, manuals and arrangement drawings.
AI-generated family illustrations. The selected configuration follows the agreed model and drawing.
manufacturing

Casting produces pump components to the construction and material requirements of the selected equipment. The applicable alloy, pattern and component geometry depend on the pump family and the agreed operating conditions.

Machining prepares mounting faces, bores, fits and connection interfaces for assembly. OEM parts should be reviewed against the approved drawing and revision, including the dimensions that determine interchange and installation.

Owner-supplied factory photograph showing pump castings staged in a work area. The exact parts and process route depend on the selected order.

Owner-supplied factory photograph showing test-control equipment. The inspection points and acceptance records must be agreed for the selected equipment.
documents
Original series manual and technical references. Review the applicable model, version and units.
Open original PDF View family brochure ↗Request the selected model curve, arrangement drawing, materials, installation instructions and agreed inspection records.
Request technical documentsquestions
medium name and composition; required flow; total head; operating temperature; suction conditions; installation arrangement; power supply and drive method; materials, standards and inspection requirements; required supply scope; well diameter and depth; static and dynamic water levels; sand content and water-quality report; cable length and wellhead arrangement. Review the complete duty on the applicable model curve.
Wetted materials selected for the liquid and temperature. Model-specific submerged arrangement. Confirm compatibility with the complete liquid composition and temperature.
This page has no independently verified numerical model schedule. Request the applicable model table and curve for the proposed configuration.
Confirm pump, driver, controls, auxiliaries, spares, drawings, manuals and required test records in the agreed quotation.
enquiry
Describe the liquid, required output and site arrangement so BBP can review the model and equipment scope.