Define the selected configuration
Rotor-compressed tube or hose delivery for controlled chemical injection. Confirm tube chemistry, compression setting and replacement interval; capacity changes as the tube wears. Define the chemical, required dosing rate and discharge pressure before selecting the liquid end.
- Chemical composition, concentration and temperature
- Minimum, normal and maximum dosing rate
- Injection pressure and its operating variation
- Tank level, suction line and gas-release tendency
- Control signals, calibration and supply scope